Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Micromachines (Basel) ; 14(7)2023 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-37512725

RESUMO

(1) Background: Microfluidic chips have found extensive applications in multiple fields due to their excellent analytical performance. As an important platform for micro-mixing, the performance of micromixers has a significant impact on analysis accuracy and rate. However, existing micromixers with high mixing efficiency are accompanied by high pressure drop, which is not conducive to the integration of micro-reaction systems; (2) Methods: This paper proposed a novel "Tai Chi"-shaped planar passive micromixer with high efficiency and low pressure drop. The effect of different structural parameters was investigated, and an optimal structure was obtained. Simulations on the proposed micromixer and two other micromixers were carried out while mixing experiments on the proposed micromixer were performed. The experimental and simulation results were compared; (3) Results: The optimized values of the parameters were that the straight channel width w, ratio K of the outer and inner walls of the circular cavity, width ratio w1/w2 of the arc channel, and number N of mixing units were 200 µm, 2.9, 1/2, and 6, respectively. Moreover, the excellent performance of the proposed micromixer was verified when compared with the other two micromixers; (4) Conclusions: The mixing efficiency M at all Re studied was more than 50%, and at most Re, the M was nearly 100%. Moreover, the pressure drop was less than 18,000 Pa.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...